China Air Cooled Screw Or Scroll Chiller Manufacturers, Suppliers

If you pair one of these systems with the wrong application, it likely won’t perform properly or as efficiently as you want it to. Standard set point range is 20°F to 65°F (-7 to 18°C) with extended range from 0°F to 80°F (-18°C to 27°C). Our chillers serve many sectors including industrial manufacturing, food and beverage processing, medical and pharmaceutical products. Tubing, insulation and hose clamps—our chiller plumbing kits provide the essential accessories to keep your chiller equipment active in one convenient package. Tthe result is an easy-to-use, easy-to-maintain, high performance chiller configurable to the most demanding applications. Choose from a wide range of cooling capacities and options to create the right fit for your application. TECOCHILL RT Series Packaged Air-Cooled Chillers are sized at 50 tons and eliminate the need for cooling towers. Providing cooler water for the condense improves the chiller’s performance. It will not have to work as hard to condense the water and will run more efficiently. In some cases this technique can compensate for problems with coils.

check it out

Dual refrigeration circuits, with 1 circuit having hot gas bypass . Arrived at KIG in September 2016 was this perfect late model 40 ton Air Cooled Chiller. It has been professionally de-commissioned and has silver soldered caps on the both the chiller side and condenser side refrigerant lines. Each of the 4 condenser fans have adjustable pressure-based fan switching to tweak your outdoor year-round cooling needs even in low ambient. KIG has confirmed with Arcti Chill service that this unit can be adjusted to 28°F Glycol fluid temps with some Carel controller setting adjustments. The indoor section of the chiller features a robust shell/tube exchanger, dual 20hp Copeland Compressors, an insulated 250 gallon reservoir, and a 5 hp process pump. Arrived at KIG in October 2014 was this 2007 Trane Intellipak 30 ton Air Cooled Chiller.

Our versatile range of high efficiency air cooled, water cooled, free cooling and remote condenser chillers gives customers a wide choice of cooling capacities from 20kW up to 3MW. This kind of screw-type compressor features high cooling efficiency, low noise, and long service life to ensure your air cooled chiller smooth running, high cooling performance with energy-saving. The Chiltrix small air cooled chiller compressor is fully variable in capacity and its operation is continuously adjusted to match the required heating or cooling output, avoiding on/off cycling and wasted energy. When measured on an annual basis, the average energy savings produced by the Chiltrix dynamic capacity system can exceed 40-50%. Manufactured in the United States the Air-Cooled Chillers from BV Thermal Systems are rigorously tested to ensure that chillers meetOur requirements before we would ship any unit to you. The Air-Cooled feature a hot gas by-pass which routes the hot, uncondensed refrigerant back through a reservoir coil thus eliminating the on/off cycling of the compressor. Utilization of the hot gas by-pass allows for greater stability and thermal protection for the pump, motor and compressor. On the other hand, industrial chillers incorporate refrigeration units in their cooling setup.

Has Micro Channel Coils, Coil Guards, and Low Ambient VFD option for year round cooling even in colder climates. Arrived at KIG in April 2016 was this nice Zarsky / Cold Shot 20 ton Air Cooled Chiller. Arrived at KIG in March 2016 was this 2014 Koolant Koolers 3 Ton “AVI Series” Air Cooled Chiller. It features a cleanable heat exchanger where the plates can be disassembled. It is ideal for dirty fluid or problem fluid, yet fine for clean water/fluid of course too. It has a 1 hp pump and is a “tankless” design, intended to draw from your tank/reservoir, through the heat exchanger, then back out to your process or holding tank. This is an indoor chiller, with fluid setpoint range of 50°F to 90°F.

Once the heated air is transferred outside of the unit, it will lower in temperature and turn back into a liquid, which allows for a continuous cooling cycle. When used with these types of applications, the natural draft cooling tower will remove heat from the water via the natural convection process. Chillers take the heat out of the air and also are implemented in industrial settings to cool down equipment. This checklist is designed to help chiller owners and maintenance personnel conduct detailed and reliable maintenance on air-cooled chillers. All Kote Lining Inc. does far more than just apply protective coatings to your chiller tubes, chillers, and cooling towers. We can help you get the most out of your commercial HVAC system by helping maintain the cooling tower and the chiller systems to ensure they are performing their best, and using as little energy as necessary. Give us a call today if you need repairs or service on your chiller system.

We provided this new to one of our repeat customers, who wanted to quickly upgrade to a 10 ton outdoor rated unit; so we have this back in trade. This is a nice, basic indoor chiller, with a process temp range of 42°F to 72°F. Arrived at KIG in October 2020 is a perfect General Air Products 14 ton Air Cooled Chiller. Our 30-ton air-cooled screw chiller is just what you need for anodizing applications. Even if you find your current cooling method is working, we are confident you will find using our industrial screw chillers for your cooling needs will be far more convenient and efficient. Plating — either electroplating or electroless plating — is becoming a major industry as more industries are looking for metal finishing experts to complete their products. Plating metal requires a tremendous amount of heat, which you then must remove. You need strong industrial screw chillers for that kind of job, which is just what we provide.

Designed with a vertical air discharge design that enhances comfort in your plant by carrying heat up and away from your processes and your operators, the air-cooled chillers have a +/-1°F accuracy. To eliminate the containment such as bacteria or algae, water cooled chillers need to treat condenser water every now & then. In water cooled chillers, a pump is required to circulate the water in the system & then out of the chiller. Compared with the water-cooled chiller, the air-cooled chiller is more convenient and easy to install or maintain. R134a refrigerant charged in air cooled chillers is specifically designed for certain areas such as Middle East countries. The RMD is located immediately prior to the evaporator so that the cold gas in the evaporator can absorb heat from the water in the evaporator. There is a sensor for the RMD on the evaporator outlet side which allows the RMD to regulate the refrigerant flow based on the chiller design requirement. Water-cooled chillers are typically intended for indoor installation and operation, and are cooled by a separate condenser water loop and connected to outdoor cooling towers to expel heat to the atmosphere. Packaged Air-Cooled Chillers, the SA-Series manufactured by Whaley Products, Inc. are self-contained industrial packaged air-cooled chiller systems.

7.3.2The connector of the cooling water inlet and outlet should use a vibration absorbs connector to avoid the machine’s vibration and pipe system damaged. If there is any problem or question of your air-cooled screw chiller, please contact TopChiller or an agent right now, therefore the problem can be fixed as soon as possible. Electrical protection devices and alarm systems act to monitor, protect, and alarm. 1)It is a tube in tube structure with newly developed fire-proof and water-proof material as heat preservation. The color of the shell may design by the customer when the order is placed. The computer may also connect the network system to realize building management control automatically.

AQVL, Air cooled Chillers have been designed and optimized to operate with R410A refrigerant. Lifetime energy costs – Values represent the sum of the discounted value of annual energy costs, based on an assumed chiller life of 23 years. In the meantime, TopChiller® also provides a comprehensive range of services for pre-sales questions and after-sales issues, covering everything from product inquiries to maintenance support. TopChiller® Air Cooled Screw Chillers are aimed to optimize the energy efficiency of the target devices. If the heat exchanger of the evaporator or pipes freezes to broke, it will result in serious leaking. Pre-heat time for lubrication of the compressor according to weather and ambient environment, but preheat time cannot be less than 12 hours. After a long period of running, the inside of the pipe in the dry-type evaporator is accumulated calcium oxide or other mine substance.

Plastic machinery is also another important application for air cooled screw chillers. Air cooled screw chiller can control the temperatures of the production devices and keep the cutter at the required temperature all the time to secure the quality of the products coming out of the machines. TopChiller® air cooled screw chillers are the perfect choice to regulate the temperatures of the concrete and ensure that problems will not arise from hot concrete. The amount of water replenishment of the water cooled screw chiller is an important factor affecting its cost. When your cooling water isn’t cool enough, let a PCR Water Cooled Chiller provide the temperature you need. Condensers sized for city water, well water, cooling tower water or central chilled water systems. Whereas, air cooled chillers can operate below freezing without freeze protection issue. Since air cooled chillers do not require water, they are preferred for locations where there is shortage of water or water is very expensive.

ARANER would be happy to help you in the decision making process. Fully integrated industrial air cooled chillers arrive complete with a pump, tank and microprocessor controls. Technical Systems’ Air-Cooled Chillers have been specifically designed for commercial and industrial duty applications to provide a simple solution to your unique design. The main components of the air-cooled chiller are the cold water tank, water pump, unit, cooling equipment and link water pipe. The installation of the air-cooled chiller is very simple, it can be used normally after connecting the water pipe and the power supply. Skyline Industrial is veteran industrial chiller provider based in California that has over 10 years of experience in creating top of the line industrial chillers for any production needs. As a result of this, over 80% of our customers have become repeat buyers over the years. Rack mount recirculating laser chiller RMFL-2000 is developed by S&A Teyu based on the laser welding market demand and is applicable to cool 2KW handheld fiber laser welding machine. Rack mount water chiller RMFL-2000 features ±0.5℃ temperature stability with dual temperature control system which is capable of cooling the fiber laser and the laser head at the same time. In addition, it is designed with intelligent & constant temperature modes which can meet different demands in different situations.

See our run off videos below of similar unit already shipped to customer. Arrived at KIG in March 2016 was this never used, never installed, 2013 Koolant Koolers DVI-7500-M 7.5 ton “Drop-In” Air Cooled Chiller. This 460 Volt INDOOR chiller is designed to be lowered into your existing process tank for your process. There are two coil heat exchangers to be submerged in your oil or water-soluble fluid. Unit features a 7.5 hp scroll compressor, uses R407c refrigerant, and some nice Carel controls. Arrived at KIG in November 2018 was this 2014 Cold Shot Air Cooled Chiller. We have refurbished, tested, and supplied dozens of this brand to various industries over the years.

The refrigerant then enters the evaporator and will pass through a series of horizontal tubes which are surrounded by the “chilled water” and these will flow in the opposing, counter flow to each other. By the time the refrigerant leaves the evaporator, it will have picked up the unwanted heat from the return chilled water and will leave as a low pressure, low temperature saturated vapour. The chilled water will have given its thermal energy up to the refrigerant and will leave around 6°C (42.8°F). The refrigerant is the only fluid which moves around each of the components of the chiller. It changes its pressure, temperature, enthalpy and entroy as it moves around the machine and transports the unwanted heat away from the evaporator chilled water. From 25% to 100%, the system is always exactly the right size for the job. See the details of Chiltrix high efficiency chiller heat pump technology.